Summary
Defines possible results returned by the cross spectrum analyzer.
Unit
SignalAnalysis
Declaration
TCrossTransform = (ctInputSpectrum, ctOutputSpectrum, ctCrossSpectrum, ctCoherence, ctTransferFunction);
| Value | Description |
|---|
| ctInputSpectrum: | returns the averaged spectrum of the Input signal. |
| ctInputSpectrum: | returns the averaged spectrum of the Ouput signal. |
| ctCrossSpectrum: | returns the averaged cross spectrum. |
| ctCoherence: | returns the coherence between the input and output spectrum. Coherence will be 1 for all frequencies that were only amplified/attenuated or delayed by the "system". It can be used to test the linearity of the system being analyzed. If the system is completely linear, the coherence will be one for all the frequencies. If the system is completely non-linear the coherence will be 0 for all the frequencies. |
Description
Input signal is the "input" in to the system being analyzed and Output signal is the output from the system. For example: input in the speakers comes from the signal generator and output is captured with a microphone.